Please note that MainOne does not accept unsolicited resumes from recruitment agencies.
In the absence of a signed service agreement, MainOne will not consider or agree to any payment,
referral fee or such other compensation to a recruitment agency. In the event of the submission of an
unsolicited resume or referral from a recruitment agency without a signed service agreement,
MainOne reserves the right to pursue and hire any such candidates without any obligation (financial or otherwise)
to such recruitment agency.
In addition, MainOne does not support or approve hiring practices that obligate a candidate to pay a
portion of his/her remuneration to a recruitment agency as compensation for a referral to MainOne.
DECLARATION (Applicants)
I hereby declare that the information I will provide on my job application and supporting documents is
correct and can be relied on. If it is subsequently discovered that any statement or information is false,
misleading or copied from another source (in the case of assessments), my application may be disqualified.
Job Title: Data Center Facility/ BMS Engineer (Level 2)
Department: Technical
Location: Appolonia, Ghana
Number to Hire: 1
Job Type: Permanent
Minimum years of Experience: 4
Responsibilities
The Data Center Facility & BMS Engineer will be responsible for capacity planning and upgrade, ability to plan, and upgrade systems within the infrastructure.
Other responsibilities will include;
Carrying out troubleshooting and diagnoses of failed critical equipment and determine root cause of equipment failure, take first-line corrective action to restore the equipment and ensure reliability improvement of same equipment.
Innovate, Implement, and practice energy savings and reduce the cost of operation.
Evaluate new products and technologies to ensure efficient and effective infrastructure delivery
Provide direction for the day to day operations and monitoring of the Data Center electrical & mechanical components such as CHILLERS, CRAC/CRAH VESDA & FM200, Access Control, CCTV, Water Leakage Detection etc.
Performing, supervising, scheduling Corrective Maintenance in the Data Centers and change management
Second level troubleshooting and resolution of Mechanical and Electrical related faults relating to Generators, Chillers, HPAC/CRAC units, secondary Pumps, Extractor fans, UPS, AVR etc.
Ensures preventative and predictive maintenance program is implemented and followed throughout with support vendors as planned
Maintain adequate records for undergoing operational audits both internal as well as external
Facility vendor/Contractor supervision.
Ensure proper and effective housekeeping within the facility
Ability to monitor the delivery of service especially by 3rd party vendors rendered to customers
Qualifications, Skills & Competencies
Transferable experience of at least 4 years
The capability of creating, understanding and interpreting Single Line Diagrams with the view of resolving second level electrical issues.
Good Knowledge of BMS server, DCIM Server, NVR, CHILLERS, CRAH/CRAC, VESDA & FM200, Access Control, CCTV Systems, HVAC Systems, intrusion detection System
Excellent second level ability to troubleshoot Mechanical and Electrical systems faults within the DC infrastructure.
Good Technical Knowledge of various Electrical and Mechanical Distribution and sub systems
Capacity planning change management and ability to develop MOP for all change and plan upgrade within the infrastructure.
Strong team player
Strong organizational skills and innovative problem-solving abilities.
Good communication & interpersonal skills, multitasking with an ability to interact with a wide range of people and be a Good Team player.
Excellent logical reasoning and troubleshooting skills
B-Eng. Electrical or Mechanical Engineering
ITIL Certification and any relevant Facility Management/BMS/DCIM certification will be added advantage.
Demands of the Job
Ability and willingness to work efficiently with or without supervision